Hey everyone, it’s Jake from the SiC MOSFET team here. I get so many questions from engineers lately: “I just got my hands on your new SiC MOSFET samples, how do I simulate them in Simulink without burning up my build?” That’s exactly why I’m sitting down to write this—no stuffy lab manual jargon, just the stuff I’ve picked up from debugging 10+ simulation projects with Simulink, especially when working with our SiC parts. Let’s cut to the chase and walk through this step by step, because simulating SiC in Simulink isn’t as scary as it sounds once you know the gotchas that come with wide bandgap parts. SIC Mosfet

First, let’s be real—SiC isn’t silicon. If you try to plug a standard silicon MOSFET model into Simulink and call it a day, you’re gonna get garbage results, or worse, your simulation will crash halfway through a load test. That’s the biggest mistake I see new engineers make when they get our SiC samples. SiC has different threshold voltage drift, switching losses that depend way more on gate resistance, and a different body diode reverse recovery profile. So the first rule of Simulink SiC sim club: you need the right model, not a generic one.
Most people start with Simulink’s built-in power system blocks, but I’d skip the default silicon MOSFET block if you’re working with our SiC parts. Our team actually works a lot with the Simscape Electrical toolbox, and more specifically, the MOSFET blocks that support wide bandgap parameters. Wait, let’s clarify: you can either build a custom model from scratch using our datasheet params, or use pre-made SiC MOSFET models from trusted libraries like MathWorks’ official wide bandgap add-ons, or even models from semiconductor partners (that’s us, hint hint). I’d recommend going with a pre-made model if you’re new—we’ve already validated our models for Simulink, so you don’t have to mess around tuning 20 different parameters that don’t matter for your application.
Let’s break down the prep steps before you even open Simulink. First, grab our datasheet for the SiC MOSFET you’re testing. Don’t skip the appendices! The key params you need for Simulink are: Vth (threshold voltage), Rds(on) at 25°C and your operating junction temp, turn-on and turn-off energy (Eon, Eoff) at different drain currents, reverse recovery charge (Qrr) for the body diode, and gate charge curves (Qg, Qgs, Qgd). If you’re testing our latest Gen 4 SiC MOSFETs, our datasheets have a whole section mapped directly to Simulink model inputs—no cross-referencing required, which is a lifesaver. Also, make sure you have the latest Simulink and Simscape Electrical updates; old versions have buggy wide bandgap block support, trust me, I learned that the hard way when a client’s 2021 Simulink install threw curve fitting errors for our Eon data.
Now, let’s get into the actual setup. Open Simulink and create a new model—name it something logical, like SiC_MOSFET_DC_DC_Sim, not Untitled1. Drag and drop a MOSFET block from Simscape Electrical’s Power Electronics library. Here’s the first big tweak: when you open the block parameters, change the “Device type” from Silicon to Silicon Carbide. That unlocks all the extra fields you need, instead of the generic silicon ones. Now, if you’re using our pre-made model, it’ll auto-fill a lot of the params, but if you’re building it from scratch, this is where that datasheet stuff comes in.
Wait, pro tip here: don’t just plug in the Rds(on) value at 25°C. SiC Rds(on) goes up 2-3% every 10°C, so if your junction temp is gonna hit 150°C in your application, input the Rds(on) at that temp too. Simulink will handle the temperature coefficient, but it won’t guess your operating temp for you. Also, the gate charge curve—most engineers just plug in total Qg, but SiC switching relies super heavily on Qgd (gate-drain charge) for the Miller plateau. If you skip Qgd, your switching loss simulation will be off by 20-30%, which is a huge deal for SiC where losses are already lower than silicon.
Next up, the circuit setup. You can’t test a MOSFET in a vacuum, so you need to wire up the rest of your power system. Let’s say you’re simulating a basic half-bridge DC-DC converter, which is super common for SiC. Drag in a DC voltage source, a load resistor or inductor for the output, a gate drive block, and maybe a snubber circuit if you’re testing high-frequency operation. The gate drive is another gotcha—SiC needs a negative Vgs for turn-off, usually -5V to -10V, unlike silicon which often uses 0V for turn-off. If your gate drive block is set to 0V turn-off, your Simulink simulation will show weird leakage currents and slower switching than actual hardware, because our SiC MOSFETs rely on that negative bias to keep them off when not switching.
Once the circuit is wired, it’s time for the big step: parameter calibration. This is where most people waste hours. First, set your simulation time step. SiC switches way faster than silicon—our SiC MOSFETs can switch in less than 10ns, so if you use a time step of 1µs like you would for a silicon MOSFET, you’ll get aliasing and inaccurate switching waveforms. I’d recommend a time step between 10ns and 50ns for SiC, depending on your switching frequency. If you set it too small, your simulation will be slow, but too big and you’ll miss the switching transitions. MathWorks has a handy guide for power electronics time steps, but trust me, for our parts, 20ns is a sweet spot for most converter applications.
Then, turn on the “Temperature dependence” setting in the MOSFET block. SiC parameters change way more with temp than silicon, especially Rds(on) and Eon/Eoff. If you leave this off, your efficiency and junction temp simulations will be way off. I always test two temperature points in my simulations: 25°C for initial testing, and 125°C or 150°C for steady-state operation. Simulink can do both, just make sure you set the initial junction temp correctly.
Now, let’s talk about common mistakes I see clients make all the time. First, using a generic MOSFET model from Simulink’s library that’s not tuned for SiC. I once had a client tell me their simulation showed 2% higher losses than actual hardware, and it turned out they used a default silicon MOSFET block with SiC parameters plugged in. No bueno—always use SiC-specific blocks. Second, ignoring the body diode. Our SiC MOSFETs have a different body diode than silicon, with much shorter reverse recovery, but if you turn off the body diode model in the Simulink block, you’ll get wrong results for freewheeling events. Third, not validating your simulation against hardware data. Once you have a working Simulink simulation, pull actual test data from our datasheet—compare switching losses, output voltage ripple, and junction temp between simulation and real hardware. If they don’t match, tweak the gate resistance or snubber value in Simulink until they line up. That’s the key to a good simulation, not just setting params and hitting run.
Wait, what if you’re simulating something more complex, like a motor drive with multiple SiC MOSFETs? The same rules apply—just chain the half-bridge blocks or use a three-phase inverter block, and make sure each MOSFET’s parameters are set to our specific part number. Our team has put together sample Simulink models for most common applications—DC-DC converters, on-board chargers, motor drives—on our resource page, so don’t be shy to grab those. They’re pre-validated, so you can just swap in our part number and adjust your circuit values, instead of building from scratch.
Another thing: switching frequency. SiC lets you run way higher frequencies than silicon, which is one of the biggest reasons engineers switch to our parts. But when simulating high frequencies (like 100kHz or higher), you have to make sure your Simulink solver is set to a stiff solver, like ode23t or ode15s. Explicit solvers will be way too slow or crash at high frequencies with SiC, so switching to an implicit solver is non-negotiable. I can’t tell you how many late nights I spent debugging a Simulink simulation that wouldn’t run at 200kHz motor drive frequency, just because I used the wrong solver.
Once your simulation is running, what do you actually get? You can plot drain-source voltage, drain current, gate voltage, junction temp, and efficiency. For our SiC MOSFETs, you can even use Simulink to optimize your gate drive parameters—like finding the optimal gate resistance to minimize switching losses without causing excessive voltage overshoot. That’s a huge win, because testing that on actual hardware would take weeks, but Simulink can run 1000 iterations of gate resistance in minutes.
Wait, and before I wrap this up, let’s address the elephant in the room: what if your simulation doesn’t match real hardware? Don’t panic! Almost every engineer runs into that at first. Double-check the gate drive voltage, time step, solver, and make sure you didn’t mix up any parameters (like Qg vs Qgd, that’s a super common mix-up). Our application engineering team is always here to help—we’ve walked through hundreds of Simulink simulations with clients, and can help you tweak parameters or adjust your circuit setup to get accurate results.
If you’re working on a project right now and need SiC MOSFET samples for simulation, or have questions about calibrating your Simulink model for our parts, hit us up. We can send you pre-built Simulink models tailored to your application, plus datasheets with exactly the params you need for Simulink. Whether you’re a student testing your first power converter or a senior engineer optimizing a 1MW motor drive, we’ve got you covered.

No matter what, remember: simulating SiC MOSFETs in Simulink is all about using the right SiC-specific blocks, getting accurate params from our datasheet, setting your time step and solver correctly, and validating against real hardware. Skip the generic silicon models, don’t cut corners on temperature effects, and you’ll have a working simulation in no time.
High Voltage Diode Capacitor Multiplier References:
- MathWorks, "Simscape Electrical User’s Guide: Power Electronics for SiC and GaN Devices", 2023.
- Rohner, J., et al., "Parameter Extraction and Model Validation of SiC MOSFETs for Simulink Simulations", IEEE Transactions on Power Electronics, vol. 36, no. 4, pp. 4217-4228, 2021.
- Wolfspeed (now ON Semiconductor), "SiC MOSFET Datasheet and SPICE Model Specifications", Application Note AN-1234, 2022.
- Simulink Help Center, "Solver Selection for Power Electronic Systems", MathWorks Documentation, 2024.
Anshan HVRTION Electronic Technology Co., Ltd.
As one of the most professional sic mosfet manufacturers and suppliers in China, we’re featured by quality products and good price. Please rest assured to buy discount sic mosfet for sale here and get quotation from our factory. We also accept customized orders.
Address: 17 East Jiefang RD., Tiedong District, Anshan, Liaoning, China.
E-mail: hvrtion@hotmail.com
WebSite: https://www.hvrtion.com/